Product Description
The dc source system's autoranging output characteristic enables unprecedented flexibility by offering a wide range of voltage and current combinations at full power. While adjustable dc regulated power supply with[rectangular," or traditional, output characteristics provide full power at only one voltage and current combination.For this model, it can meet the requirement of 100v power supply too.
Except the 40v Dc Source System,it could be also have other voltage opition for 75v Dc Source System,80v Dc Source System,kindly check more with the regional sales.
Application Area:
This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's production test as well.
Product Features:
● With accurate voltage and
current measurement capability.
● Coded Knob, multifunction
keyboard.
● Standard RS232/RS485/USB/LAN
communication interfaces, GPIB is optional.
● Remote sensing line voltage drop
compensation.
● Equips with LIST waveform editing
function.
● Use the Standard Commands for
Programmable Instrumentation(SCPI) communication
protocol.
● Have obtained CE
certification.
Technical Specification:
ltem | MODEL | SYS40VDC24000W | |
INPUT | |||
1 | Voltage | 190~265VAC | |
2 | Frequency | 47~63Hz | |
3 | Phase | 3 Phase,4Wire+Groud/Y Connect | |
4 | Max.Current | 150A | |
5 | Input Power Max | 28.5kW | |
6 |
Power Factor at 220VAC Input ,Full Load |
0.98 Min. Active PFC | |
7 | Efficiency | >88% Max @Full Load and Units=4kW Model | |
OUTNPUT (Parallel Mode) | |||
8 | Output Voltage | 0~40V | |
9 | Output Current | 0~720A | |
10 | Output Power | 24kW Max | |
11 | Load Regulation | Voltage | 240mV |
12 | Current | 0.75A | |
13 | Line Regulation | Voltage | 0.02%F.S.+30mV |
14 | Current | 0.02%F.S.+15mA | |
15 | Voltage Setting | Range | 0~40V |
16 | Resolution | 0.1mV | |
17 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
18 | Current Setting | Range | 0~720A |
19 | Resolution | 10mA | |
20 | Accuracy | 0.1%+0.10%F.S | |
21 | Ripple | Voltage | 80mVp-p/12mVrms |
22 | Current | 450mA(Full Range),60mA(TYP Value) | |
MEASUREMENT (Parallel Mode) | |||
23 | Voltage Setting | Range | 0~40V |
24 | Resolution | 0.1mV | |
25 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc |
|
26 | Current Setting | Range | 0~720A |
27 | Resolution | 10mA | |
28 | Accuracy | 0.1%+0.10%F.S | |
OUTNPUT (Series Mode) | |||
29 | Output Voltage | 0~240V | |
30 | Output Current | 0~120A | |
31 | Output Power | 24kW Max | |
32 | Load Regulation | Voltage | 240mV |
33 | Current | 0.75A | |
34 | Line Regulation | Voltage | 0.02%F.S.+30mV |
35 | Current | 0.02%F.S.+15mA | |
36 | Voltage Setting | Range | 0~240V |
37 | Resolution | 10mV | |
38 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
39 | Current Setting | Range | 0~120A |
40 | Resolution | 1mA | |
41 | Accuracy | 0.1%+0.10%F.S | |
42 | Ripple | Voltage | 120mVp-p/18mVrms |
43 | Current | 300mA(Full Range),40mA(TYP Value) | |
MEASUREMENT (Series Mode) | |||
44 | Voltage Setting | Range | 0~240V |
45 | Resolution | 10mV | |
46 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
47 | Current Setting | Range | 0~120A |
48 | Resolution | 1mA | |
49 | Accuracy | 0.1%+0.10%F.S | |
Extra Function | |||
50 | Remote Sense | Range | 5V(DC), Max. Total power less than rated power |
51 | Comm. Respondence. | 50ms | |
52 | Graphic Display | VFD | |
53 | Operation Key Feature | Soft key,Numberic key,Rotary Knob | |
54 | Rack mount Handles | Yes | |
55 | FAN | Temperature Control | |
56 | Protection Circuits | OCP, OVP, OPP, OTP,FAN | |
57 | Interface | USB, RS485, RS232, LAN(Standard); GPIB(Option) | |
Remote Control Input/Output signal characteristics | |||
58 | Remote Input signal | Not Support | |
59 | Remote output signal | Not Support | |
Environmental | |||
60 | Operating Temperature | 0°C~40°C | |
61 | Storage Temperature | -20°C~70°C | |
62 | Altitude | 2000m | |
63 | Relative Humidity | 10%~90%, non-condensing | |
64 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current | |
Mechanical | |||
65 | Dimensions(W*H*D) | 600.0*1064.0*700.0 mm | |
66 | Package Dimensions(W*H*D) | 720.0*1240.0*820.0 mm | |
67 | Unit Net Weight | 100.0kg+15kg*N(REF) | |
68 | Accessories Weight | 0.4kg | |
69 | Shipping Weight | 160.0kg+15kg*N(REF) | |
Regulatory Compliance | |||
70 | CE Mark | Installation Overvltage Category II;Class II equipment;indoor use only. |
*F.S. represents the maximum value
of the output range.
*N stands for the
number of installed power supply units,and N is greater than 1.