Basic Info
Model No.: SP300VAC1000W
Additional Info
Packaging: cartons
Transportation: Air
Port: DHL
Product Description
APM programmable ac source covers power range from 600VA up to 5000VA in switching technology;This one-phase input models AP30VAC1000W can output voltage from 0~30VAC. The product comes with many communication interface for PC control ,like RS232,RS485,USB interface as standard and GPIB , LAN interface as optional.High frequency ac power supply up to 1200hz for professional version.
There are more models. 600W AC Power Supply, 1200W AC Power Supply, 1500W AC Power Supply,3000w Ac Power Supply, 4000W AC Power Supply for your reference.
Application Area:
This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's production test as well.
Product Features:
● Built-in power sweeping function.● Built-in Transient mode.
● Built-in Dimmer function.
● With reverse current protection to avoid current flowing backward.
● Built-in power meter, which is capable of measuring 15 electrical parameters, including voltage, current, frequency, etc.
● Built-in IEC61000-3-3/ IEC61000-3-2/ IEC61000-4-11/ IEC61000-4-14/ IEC61000-4-28/ IEC61000-4-13 standard test required waveform.
● 4.3" large touch color screen, possess complete functions and easy to operate.
● Support for USB data import/export and screen snap from front panel.
● AC+DC mixed or independent output mode for voltage DC offset simulation.
● Capable of setting voltage and current output restriction, support for constant current output mode.
● Capable of setting output slope of voltage and frequency.
● Capable of setting ON/OFF phase angle.
● Support for LIST/PULSE/STEP mode, simple time setting and circulation setting, which is suitable for power line disturbance simulation test.
Basic Functions:
1. Adjustable Phase Angle/Slope
Adjustable Phase Angle/Slope is applicable to verification test of ON/OFF inrush current testing. This function is applicable to start inductive or capacitive load with large capacity to avoid high current when instantaneously start the device.
2. High Output Current Crest Factor
The surge current could reach 5-6 times of the rated current, especially suitable for inrush current testing.
3. Transient mode
Transient mode simulates the impact on test object when turn on or turn off transient high power capacity load in power grid.
4. Dimmer Function
Support Dimmer function, which is applicable to conduct speed regulating or dimming verification test for electric motor, lamp and other products.
5. Output Simulation Sequence and Disturbance Simulation
Capable of simulating power line disturbance simulation test.
Advanced Functions:
1.Output Impedance(Applicable to Professional Version)
Support Simulating Output Impedance.
2.Built-in IEC Standard Test(Applicable to Professional Version)
Built-in IEC standard test could be recalled directly.
3. Amplifier Function
The programmable AC power source could realize real time output by tail after signal waveform.
4. Harmonics/ Inter-harmonics Generate Simulation and Harmonics Measurement(Applicable to Professional Version)
Up to 40 orders of harmonics components, applicable to interference simulation test.
5. External Control Function
Programmable AC power sources could provide analog input under test simulation of PASS, FALL and RUN status and user can control ON/OFF externally, force to shutdown, reset and upload 7 sets of stored parameters.
Technical Specification:
at
220VAC Input ,
Rise time/
1Hz
at 100~1000Hz,
Output
& Inter-
harmonics
1Hz
at 100~1000Hz,
Model
SP300VAC1000W
Advanced
SP300VAC1000W
Professional
INPUT
1
Voltage
90~265VAC
2
Frequency
47~63Hz
3
Phase
1 Phase,
2Wire+Groud
4
Max.
Current
15A
5
Power
Factor
Full Load
≥0.98 Active
PFC
6
Efficiency
>85.5%
(Peak)
>85% at 220VAC,50Hz input/230VAC,50Hz output, Full
Load
OUTPUT
7
AC
Power
1000VA
8
Max.
Current
(r.m.s)
0~150V(L)
9.2A
0~300V(H)
4.6A
9
Max.
Current
(Peak)
0~150V(L)
55.2A
0~300V(H)
27.6A
10
Phase
1
Phase
11
Crest
Factor(CF)
<6
12
Load
Regulation
±0.1%F.S.(Resistive Load) at
15-70Hz
±0.5%F.S.(Resistive Load) at 70.1-1200Hz
Note:1001~1200Hz only
available to Professional Version Models
13
Line
Regulation
±0.1V
14
Voltage(AC)
Range
0~300VAC, 150V/300V/Auto
Mode
Resolution
0.1V
Accuracy
0.2% of setting
+0.2%F.S.
15
Voltage(DC)
Range
0~424VDC
Resolution
0.1V
Accuracy
0.2% of setting
+0.2%F.S.
Max.
Power
1000W
Max. Current
(L/H Range)
L
6.5A
H
3.3A
drop time
<250us
16
Current OC
Fold
Mode
Resolution
0.01A
Accuracy
0.5% of setting
+1.0%F.S.
Response
Time
<1400ms
17
Frequency
Range
15~1000Hz Full Range
ADJ
15~1200Hz Full Range
ADJ
Resolution
0.1Hz at
15.0~99.9Hz,
1Hz at 100~1000Hz
0.1Hz at 15.0~99.9Hz,
Accuracy
0.03% of
setting
18
Programmable
Range
N/A
0Ω +0mH~1Ω
+1mH
19
Harmonic
Range
N/A
2400Hz
MEASUREMENT
20
Voltage
Range
AC 0~300VAC
DC
0~424VDC
Resolution
0.1V
Accuracy
0.2% of setting
+0.2%F.S.
21
Frequency
Range
15~1000Hz
15~1200Hz
Resolution
0.1Hz at
15.0~99.9Hz,
1Hz at 100~1000Hz
0.1Hz at
15.0~99.9Hz,
Accuracy
0.1% of
setting
22
Current
(r.m.s)
Range
H
0.1A~9.2A
M -
L 0.05A~3A
mA -
Resolution
0.01A
Accuracy
0.4%+1.0%F.S.
23
Current
(Peak)
Range
0A~55.2A
Resolution
0.01A
Accuracy
H 0.4%+1.0%F.S.
L
0.4%+1.5%F.S.
24
Power
Range
0~1000W
Resolution
0.1W
Accuracy
0.4% of setting +1.0%F.S.
at PF>0.2, Voltage >5V
25
Harmonic
Range
N/A
2~40
orders
GENERAL
26
Parallel Output for 1
Phase
Not
Support
27
Series Output for 1
Phase
Not
Support
28
Link Output for 3
Phase
Not
Support
29
FAN
Temperature
Control
30
Protection
Circuits
OCP, OVP, OPP, OTP, RCP,
PRI_UVP, PRI_OVP, PRI_OTP, PRI_OCP, USB_OCP
31
Interface
USB, RS485,
RS232(Standard); GPIB,LAN (Optional)
ENVIRONMENTAL
32
Operating
Temperature
0°C to
40°C
33
Storage
Temperature
-40°C to
85°C
34
Noise
73dBA(Max fan
speed)
35
Altitude
2000m
36
Relative
Humidity
5%~95%,
non-condensing
37
Temperature
Coefficient
100ppm/°C at Voltage,
300ppm/°C at Current, 100ppm/°C at Frequency
MECHANICAL
38
Dimensions(W*H*D)
483*87*636mm
39
Unit Net
Weight
15.9kg
*Note:The tolerance will
change slightly in high frequency condition.
CONTACT US
APM Technologies (Dongguan) Co., Ltd
Contact Person: Emily Cui
Phone:86-769-22028588-2892
Fax:86-769-22026771
Address: #7,Link Information Industry Park, Shuilianshan Road, Nancheng,Dongguan,Guangdong