Basic Info
Model No.: SP300VAC600W
Additional Info
Packaging: cartons
Transportation: Air
Port: DHL
Product Description
Find your small ac power supply easily amongst APM products here! It uses high frequency PWM technology ,active PFC design to deliver the low power source. The SP300VAC600W feature a digital control unit, which displays set values of voltage, current and frequency, as well as actual values of output voltage, current, power and power factor etc. 15 electrical parameters.
Except the 600w Ac Power Supply,it could be also have higher power opition for 1000w Ac Power Supply,2000w Ac Power Supply,3000w Ac Power Supply,kindly check more with the regional sales.
Application Area:
This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's production test as well.
Product Features:
● 4.3" large touch color screen, possess complete
functions and easy to operate.
● Support for USB
data import/export and screen snap from front panel.
● AC+DC mixed or
independent output mode for voltage DC offset simulation.
● Capable of
setting voltage and current
output restriction, support for constant current output mode.
● Capable of
setting output slope of voltage and frequency.
● Capable of
setting ON/OFF phase angle.
● Support for
LIST/PULSE/STEP mode, simple time setting and circulation setting, which is suitable for power line disturbance
simulation test.
● Built-in power
sweeping function.
● Built-in
Transient mode.
● Built-in Dimmer
function.
● With reverse
current protection to avoid current flowing backward.
● Built-in power
meter, which is capable of measuring 15 electrical parameters,
including voltage, current, frequency, etc.
● Built-in
IEC61000-3-3/ IEC61000-3-2/ IEC61000-4-11/ IEC61000-4-14/ IEC61000-4-28/
IEC61000-4-13 standard test required waveform.
Basic Functions:
1. Adjustable Phase Angle/Slope
Adjustable Phase Angle/Slope is applicable to verification test of ON/OFF inrush current testing. This function is applicable to start inductive or capacitive load with large capacity to avoid high current when instantaneously start the device.
2. High Output Current Crest Factor
The surge current could reach 5-6 times of the rated current, especially suitable for inrush current testing.
3. Transient mode
Transient mode simulates the impact on test object when turn on or turn off transient high power capacity load in power grid.
4. Dimmer Function
Support Dimmer function, which is applicable to conduct speed regulating or dimming verification test for electric motor, lamp and other products.
5. Output Simulation Sequence and Disturbance Simulation
Capable of simulating power line disturbance simulation test.
Advanced Functions:
1.Output Impedance(Applicable to Professional Version)
Support Simulating Output Impedance.
2.Built-in IEC Standard Test(Applicable to Professional Version)
Built-in IEC standard test could be recalled directly.
3. Amplifier Function
The programmable AC power source could realize real time output by tail after signal waveform.
4. Harmonics/ Inter-harmonics Generate Simulation and Harmonics Measurement(Applicable to Professional Version)
Up to 40 orders of harmonics components, applicable to interference simulation test.
5. External Control Function
Programmable AC power sources could provide analog input under test simulation of PASS, FALL and RUN status and user can control ON/OFF externally, force to shutdown, reset and upload 7 sets of stored parameters.
Technical Specification:
Model |
SP300VAC600W Advanced |
SP300VAC600W Professional |
||
INPUT | ||||
1 | Voltage | 90~265VAC | ||
2 | Frequency | 47~63Hz | ||
3 | Phase | 1 Phase, 2Wire+Groud | ||
4 | Max. Current | 10A | ||
5 |
Power
Factor
at
220VAC Input , |
≥0.96 Active PFC | ||
6 | Efficiency |
>81%
(Peak) >80% at 220VAC,50Hz input/230VAC,50Hz output, Full Load |
||
OUTPUT | ||||
7 | AC Power | 600VA | ||
8 |
Max.
Current (r.m.s) |
0~150V(L) | 5.6A | |
0~300V(H) | 2.8A | |||
9 |
Max.
Current (Peak) |
0~150V(L) | 32.4A | |
0~300V(H) | 16.2A | |||
10 | Phase | 1 Phase | ||
11 | Crest Factor(CF) | <6 | ||
12 | Load Regulation |
±0.1%F.S.(Resistive Load) at
15-70Hz ±0.5%F.S.(Resistive Load) at 70.1-1200Hz Note:1001~1200Hz only available to Professional Version Models |
||
13 | Line Regulation | ±0.1V | ||
14 | Voltage(AC) | Range | 0~300VAC, 150V/300V/Auto Mode | |
Resolution | 0.1V | |||
Accuracy | 0.2% of setting +0.2%F.S. | |||
15 | Voltage(DC) | Range | 0~424VDC | |
Resolution | 0.1V | |||
Accuracy | 0.2% of setting +0.2%F.S. | |||
Max. Power | 600W | |||
Max. Current (L/H Range) |
L 3.96A | |||
H 1.89A | ||||
Rise time/ |
<250us | |||
16 |
Current OC Fold Mode |
Resolution | 0.01A | |
Accuracy | 0.5% of setting +1.0%F.S. | |||
Response Time |
<1400ms | |||
17 | Frequency | Range | 15~1000Hz Full Range ADJ | 15~1200Hz Full Range ADJ |
Resolution |
0.1Hz at
15.0~99.9Hz, 1Hz at 100~1000Hz |
0.1Hz at 15.0~99.9Hz,
1Hz at 100~1000Hz, 5Hz at 1001~1200Hz |
||
Accuracy | 0.03% of setting | |||
18 |
Programmable
Output Impedance |
Range | N/A | 0Ω +0mH~1Ω +1mH |
19 |
Harmonic
& Inter- harmonics Simulation |
Range | N/A | 2400Hz |
MEASUREMENT | ||||
20 | Voltage | Range |
AC 0~300VAC DC 0~424VDC |
|
Resolution | 0.1V | |||
Accuracy | 0.2% of setting +0.2%F.S. | |||
21 | Frequency | Range | 15~1000Hz | 15~1200Hz |
Resolution |
0.1Hz at
15.0~99.9Hz, 1Hz at 100~1000Hz |
0.1Hz at
15.0~99.9Hz,
1Hz at 100~1000Hz, 5Hz at 1001~1200Hz |
||
Accuracy | 0.1% of setting | |||
22 |
Current (r.m.s) |
Range | H 0.1A~5.6A | |
M - | ||||
L 0.05A~3A | ||||
mA - | ||||
Resolution | 0.01A | |||
Accuracy | 0.4%+1.0%F.S. | |||
23 |
Current (Peak) |
Range | 0A~32.4A | |
Resolution | 0.01A | |||
Accuracy |
H 0.4%+1.0%F.S. L 0.4%+1.5%F.S. |
|||
24 | Power | Range | 0~600W | |
Resolution | 0.1W | |||
Accuracy | 0.4% of setting +1.0%F.S. at PF>0.2, Voltage >5V | |||
25 | Harmonic | Range | N/A | 2~40 orders |
GENERAL | ||||
26 | Parallel Output for 1 Phase | Not Support | ||
27 | Series Output for 1 Phase | Not Support | ||
28 | Link Output for 3 Phase | Not Support | ||
29 | FAN | Temperature Control | ||
30 | Protection Circuits | OCP, OVP, OPP, OTP, RCP, PRI_UVP, PRI_OVP, PRI_OTP, PRI_OCP, USB_OCP | ||
31 | Interface | USB, RS485, RS232(Standard); GPIB,LAN (Optional) | ||
ENVIRONMENTAL | ||||
32 | Operating Temperature | 0°C to 40°C | ||
33 | Storage Temperature | -40°C to 85°C | ||
34 | Noise | 73dBA(Max fan speed) | ||
35 | Altitude | 2000m | ||
36 | Relative Humidity | 5%~95%, non-condensing | ||
37 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current, 100ppm/°C at Frequency | ||
MECHANICAL | ||||
38 | Dimensions(W*H*D) | 483*87*636mm | ||
39 | Unit Net Weight | 15.9kg |
CONTACT US
APM Technologies (Dongguan) Co., Ltd
Contact Person: Emily Cui
Phone:86-769-22028588-2892
Fax:86-769-22026771
Address: #7,Link Information Industry Park, Shuilianshan Road, Nancheng,Dongguan,Guangdong