Basic Info
Model No.: SYS120VDC12000W
Additional Info
Packaging: cartons
Transportation: Air
Product Description
Stop worrying choosing what kind of variable volt dc power supply. Here APM and its distributors can offer you the good solution to meet different test demand. 6U high dc source system delivers maximum power 12KW as 3 units of single model 4kW connected in series or parallel. Max current 120A with 120V and max voltage 360V with 120A when connected in parallel or series. Other features can be found as below.
There are more models, 40v Dc Source System,75v Dc Source System, 150v Dc Source System,200v Dc Source System,600v Dc Source System, 800v Dc Source System for your reference.
Application Area:
This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's production test as well.
Product Features:
● With accurate voltage and
current measurement capability.
● Coded Knob, multifunction
keyboard.
● Standard RS232/RS485/USB/LAN
communication interfaces, GPIB is optional.
● Remote sensing line voltage drop
compensation.
● Equips with LIST waveform editing
function.
● Use the Standard Commands for
Programmable Instrumentation(SCPI) communication
protocol.
● Have obtained CE
certification.
Technical Specification:
ltem | MODEL | SYS120VDC12000W | |
INPUT | |||
1 | Voltage | 190~265VAC | |
2 | Frequency | 47~63Hz | |
3 | Phase | 3 Phase,4Wire+Groud/Y Connect | |
4 | Max.Current | 75A | |
5 | Input Power Max | 15kW | |
6 |
Power Factor at 220VAC Input ,Full Load |
0.98 Min. Active PFC | |
7 | Efficiency | >88% Max @Full Load and Units=4kW Model | |
OUTNPUT (Parallel Mode) | |||
8 | Output Voltage | 0~120V | |
9 | Output Current | 0~120A | |
10 | Output Power | 12kW Max | |
11 | Load Regulation | Voltage | 120mV |
12 | Current | 0.12A | |
13 | Line Regulation | Voltage | 0.02%F.S.+30mV |
14 | Current | 0.02%F.S.+15mA | |
15 | Voltage Setting | Range | 0~120V |
16 | Resolution | 1mV | |
17 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
18 | Current Setting | Range | 0~120A |
19 | Resolution | 10mA | |
20 | Accuracy | 0.1%+0.10%F.S | |
21 | Ripple | Voltage | 160mVp-p/30mVrms |
22 | Current | 90mA(Full Range),15mA(TYP Value) | |
MEASUREMENT (Parallel Mode) | |||
23 | Voltage Setting | Range | 0~120V |
24 | Resolution | 1mV | |
25 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc |
|
26 | Current Setting | Range | 0~120A |
27 | Resolution | 10mA | |
28 | Accuracy | 0.1%+0.10%F.S | |
OUTNPUT (Series Mode) | |||
29 | Output Voltage | 0~360V | |
30 | Output Current | 0~40A | |
31 | Output Power | 12kW Max | |
32 | Load Regulation | Voltage | 120mV |
33 | Current | 0.12A | |
34 | Line Regulation | Voltage | 0.02%F.S.+30mV |
35 | Current | 0.02%F.S.+15mA | |
36 | Voltage Setting | Range | 0~360V |
37 | Resolution | 10mV | |
38 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
39 | Current Setting | Range | 0~40A |
40 | Resolution | 0.1mA | |
41 | Accuracy | 0.1%+0.10%F.S | |
42 | Ripple | Voltage | 120mVp-p/22.5mVrms |
43 | Current | 120mA(Full Range),20mA(TYP Value) | |
MEASUREMENT (Series Mode) | |||
44 | Voltage Setting | Range | 0~360V |
45 | Resolution | 10mV | |
46 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
47 | Current Setting | Range | 0~40A |
48 | Resolution | 0.1mA | |
49 | Accuracy | 0.1%+0.10%F.S | |
Extra Function | |||
50 | Remote Sense | Range | 5V(DC), Max. Total power less than rated power |
51 | Comm. Respondence. | 50ms | |
52 | Graphic Display | VFD | |
53 | Operation Key Feature | Soft key,Numberic key,Rotary Knob | |
54 | Rack mount Handles | Yes | |
55 | FAN | Temperature Control | |
56 | Protection Circuits | OCP, OVP, OPP, OTP,FAN | |
57 | Interface | USB, RS485, RS232, LAN(Standard); GPIB(Option) | |
Remote Control Input/Output signal characteristics | |||
58 | Remote Input signal | Not Support | |
59 | Remote output signal | Not Support | |
Environmental | |||
60 | Operating Temperature | 0°C~40°C | |
61 | Storage Temperature | -20°C~70°C | |
62 | Altitude | 2000m | |
63 | Relative Humidity | 10%~90%, non-condensing | |
64 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current | |
Mechanical | |||
65 | Dimensions(W*H*D) | 600.0*736.0*700.0 mm | |
66 | Package Dimensions(W*H*D) | 720.0*910.0*820.0 mm | |
67 | Unit Net Weight | 54kg+15kg*N(REF) | |
68 | Accessories Weight | 0.4kg | |
69 | Shipping Weight | 94kg+15kg*N(REF) | |
Regulatory Compliance | |||
70 | CE Mark | Installation Overvltage Category II;Class II equipment;indoor use only. |
CONTACT US
APM Technologies (Dongguan) Co., Ltd
Contact Person: Emily Cui
Phone:86-769-22028588-2892
Fax:86-769-22026771
Address: #7,Link Information Industry Park, Shuilianshan Road, Nancheng,Dongguan,Guangdong